    NRC Issues Event Notification for Beaver Valley in Pennsylvania


    November 19, 2021 - Targeted News Service

     

      WASHINGTON, Nov. 15 -- The Nuclear Regulatory Commission issued the following event notification (No. 55572) involving Beaver Valley, Pennsylvania:

      MANUAL REACTOR TRIP DUE TO INCREASING STEAM GENERATOR WATER LEVELS

      "At 1007 EST on November 12, 2021, with Unit 2 in Mode 1 at approximately 17 percent power following a refueling outage, the reactor was manually tripped due to increasing steam generator water levels due to an oscillating Main Feedwater Pump Recirculation Valve. Additionally, the Main Steam Isolation Valves were manually closed to prevent excessive reactor coolant system cooldown. Decay heat is being removed by discharging steam to the atmosphere using the Atmospheric Dump Valves.

      "The trip was not complex, with all systems responding normally post-trip. There was no equipment inoperable prior to the event that contributed to the reactor trip or adversely impacted plant response. Operations responded and stabilized the plant.

      "Beaver Valley Power Station Unit 1 is unaffected and remains at 100 percent power in Mode 1.

      "Due to the Reactor Protection System actuation while critical, this event is being reported as a four-hour, non-emergency notification, per 10 CFR 50.72(b)(2)(iv)(B).

      "There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified."

      Power Reactor

      Event Number: 55572

      Facility: Beaver Valley

      Region: 1

      State: PA

      Unit: [2] [] []

      RX Type: [1] W-3-LP,[2] W-3-LP

      NRC Notified By: Sean McGee

      HQ OPS Officer: Donald Norwood

      Notification Date: 11/12/2021

      Notification Time: 13:52 [ET]

      Event Date: 11/12/2021

      Event Time: 10:07 [EST]

      Last Update Date: 11/12/2021

      Emergency Class: Non Emergency

      10 CFR Section:

      50.72(b)(2)(iv)(B) - RPS Actuation - Critical

      Person (Organization):

      Henrion, Mark (R1)

      Table omitted: https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2021/2...

    TOP

    Other Articles - Generation


    TOP

       Home  -  Feedback  -  Contact Us  -  Safe Sender  -  About Energy Central   
    Copyright © 1996-2022 by CyberTech, Inc. All rights reserved.
    Energy Central® and Energy Central Professional® are registered trademarks of CyberTech, Incorporated. Data and information is provided for informational purposes only, and is not intended for trading purposes. CyberTech does not warrant that the information or services of Energy Central will meet any specific requirements; nor will it be error free or uninterrupted; nor shall CyberTech be liable for any indirect, incidental or consequential damages (including lost data, information or profits) sustained or incurred in connection with the use of, operation of, or inability to use Energy Central. Other terms of use may apply. Membership information is confidential and subject to our privacy agreement.