Energy Central Professional

 

Australian Daily Wind Power Generation Data – Monday 30 May 2022


PA Pundits  

 

    By Anton Lang ~

    This Post details the daily wind power generation data for the AEMO coverage area in Australia. For the background information, refer to the Introductory Post at this link.

    Each image is shown here at a smaller size to fit on the page alongside the data for that day. If you click on each image, it will open on a new page and at a larger size so you can better see the detail.

    Note also that on some days, there will be a scale change for the main wind power image, and that even though images may look similar in shape for the power generation black line on the graph when compared to other days, that scale (the total power shown on the left hand vertical axis) has been changed to show the graph at a larger size to better fit the image for that graph.

    Monday 30 May 2022

    Total Wind Power Generation

    This image shows the total power generated across the whole day by every wind plant in this vast AEMO coverage area for Australia.

    The total Nameplate for all these wind plants changes as each new wind plant comes on line delivering power to the grid. That current Nameplate is 8587MW, and this is from the current total of 69 wind plants.

    Note that the shape of this wind power load curve does not follow the shape of the main load curve for total power generation, and that is seen in the image below, the solid black line across the top of the image for that graph. Wind power generates its power only when the wind is blowing, hence it does not follow the actual power generation Load Curve, which is also the the exact same shaped curve as for actual power consumption.

    For this data, I have added the times for the daily minimum, and the daily maximum, to show how they do not correlate with the actual times of minimum power consumption (around 4AM each day) and maximum power consumption, the evening Peak. (at around 6.40PM in Winter and earlier during the Summer Months.)

    Daily Minimum – 2738MW (11.25AM)

    Daily Maximum – 5287MW (11.59PM)

    Average Wind Generation – 3674MW

    Total Generated Power – 88.17GWH

    Percentage Supplied By Wind Power At The Low Point For The Day – 10.1%

    Percentage Supplied By Wind Power At Peak Power For The Day – 3395MW of 31095MW – 6.05PM – 10.92% (Mid afternoon Peak with rooftop solar added was 28545MW at 10.50AM)

    Average Percentage Of Overall Total Power Generation – %

    Daily Operational Capacity Factor – 42.79%

    Wind Power Generation Versus Total Power Generation

    This image shows the total power generated from all the wind plants in this AEMO coverage area, and compares it to the overall total generated power from every source of power generation, which is the black line at the top of the graph. Wind power is the green coloured area, along the bottom of this graph.

    While the green colour in this image looks to be a different shape to the graph above, keep in mind here that the scale is completely different, and that green coloured Wind total is the same as for the image shown above, only with the scale changed so it can fit onto the graph.

    Notes

    1. Finding Wind Power Average – On the graph, there are 25 hourly time points, starting with midnight and finishing with midnight. I have added the total at each of those hourly time points together, and divided the resultant total by 25 to give an average in MegaWatts. (MW)
    2. For total power in GWH, multiply the average daily power by 24, and then divide by 1000.
    3. For the Capacity Factor, that is calculated by dividing the average wind generation by the current Nameplate and then multiplying that by 100 to give a percentage.

    Comments For This Day

    Wind generation was higher on this day than it was on the day before, and the average power generation for this day of 3674MW gave wind generation a daily operational Capacity Factor of 42.8%, and that was twelve percent higher than the year round average. Wind was a little lower than the daily average at the usual time of the evening Peak of maximum power consumption, and at that time, wind was delivering just under 11% of all the generated power from every source. Of note here is that this was the first really cold day of the year, as the cold came in from the South, and because of that the evening Peak for this day was over that all important 3000MW mark, at 31,095MW. There was again a substantial difference between the low for the day and the high, and for this day that gap was 2549MW.

    *****

    Anton Lang uses the screen name of TonyfromOz, and he writes at this site, PA Pundits International on topics related to electrical power generation, from all sources, concentrating mainly on Renewable Power, and how the two most favoured methods of renewable power generation, Wind Power and all versions of Solar Power, fail comprehensively to deliver levels of power required to replace traditional power generation. His Bio is at this link.

    OzWindPowerGenerationTFO


    The views expressed in content distributed by Newstex and its re-distributors (collectively, "Newstex Authoritative Content") are solely those of the respective author(s) and not necessarily the views of Newstex et al. It is provided as general information only on an "AS IS" basis, without warranties and conferring no rights, which should not be relied upon as professional advice. Newstex et al. make no claims, promises or guarantees regarding its accuracy or completeness, nor as to the quality of the opinions and commentary contained therein.

TOP


Copyright © 1996-2022 by CyberTech, Inc. All rights reserved.
Energy Central® and Energy Central Professional® are registered trademarks of CyberTech, Incorporated. Data and information is provided for informational purposes only, and is not intended for trading purposes. CyberTech does not warrant that the information or services of Energy Central will meet any specific requirements; nor will it be error free or uninterrupted; nor shall CyberTech be liable for any indirect, incidental or consequential damages (including lost data, information or profits) sustained or incurred in connection with the use of, operation of, or inability to use Energy Central. Other terms of use may apply. Membership information is confidential and subject to our privacy agreement.